The tekmarNet® 2 Thermostat 529 is designed to operate mechanical equipment to deliver 2 stages of heat to a single zone within a hydronic heating system. It can be used with any terminal unit type, including radiant floor, baseboard, and fan coils. It is capable of controlling up to 2 stages of heat using zone valves or zone pumps through a tekmarNet® 2 Wiring Center or Zone Manager in order to maintain air and an auxiliary temperature. That temperature is typically a floor temperature, but could also be a remote air sensor. An optional Adaptor Plate 007 is available which allows the thermostat to be installed onto a single gang electrical box.
- Submittal Sheet
- Installation
- Quick Setup
- User Manual
Features
-
1 auxiliary sensor input
-
Air Group member
-
Auto Heating Cycle
-
Backlight
-
CSA C US Approved for use in USA and Canada
-
Exercising
-
Floor Warming (with 079 Slab Sensor)
-
Freeze Protection
-
Intelligent Setback (with tekmar 033 timer)
-
One touch overrides (with optional User Switch)
-
Outdoor Temperature display
-
Pulse Width Modulation
-
Requires 2 wires
-
Room Temperature Limiting
-
Two stage heat
-
Zone Post Purge
-
Zone Synchronization
-
tekmarNet® 2 Communication compatible
Specifications
Control | Microprocessor control. This is not a safety (limit) control |
Packaged weight | 0.8 lb. (380 g) |
Dimensions | 2-7/8″ H x 2-7/8″ W x 13/16″ D (73 x 73 x 21 mm) |
Enclosure | White PVC plastic, NEMA type 1 |
Approvals | CSA C US, meets Class B: ICES & FCC Part 15 |
Ambient conditions | Indoor use only, 32 to 122°F (0 to 50°C), RH ≤80% to 88°F (31°C), down to 50% above 104°F (40°C), Altitude <6560 ft. (2000 m), Installation Category II, Pollution Degree |
Power supply | 2 VA Provided by tekmarNet®2 Control, 1.3 VA |
Rh – W2 Relay | 24 V (ac) 2 A |
Sensors | NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892 |
-Included | None |
-Optional | tekmar type # 070, 072, 073, 076, 077, 079, 084 |